z-logo
open-access-imgOpen Access
Evaluation of the fit of the reprocessed maxillary complete denture bases
Author(s) -
R. Balasubramanian,
Manoharan PS,
R Priyanka
Publication year - 2013
Publication title -
journal of scientific dentistry
Language(s) - English
Resource type - Journals
eISSN - 2278-3865
pISSN - 2277-7687
DOI - 10.5005/jsd-3-1-1
Subject(s) - orthodontics , dentistry , computer science , medicine
Evaluation of the fit of the reprocessed maxillary complete denture bases Manoharan PS, Priyanka R, Balasubramanian R ABSTRACT: Background: Reprocessing the permanent denture base after try-in is a common procedure in the complete denture fabrication. It is speculated that subjecting polymerized Poly-methyl methacrylate resin again to heat, during reprocessing can induce dimensional changes and a significant loss of intimate fit in the denture base to the tissues, can ultimately reduce the retention and stability of the complete denture. Aim and Objectives: The aim of the study is to evaluate the effect of reprocessing on the accuracy of fit of permanent poly-methyl methacrylate denture bases. Material and Methods: A resin edentulous maxillary model was duplicated and a total of twenty casts were poured with type III gypsum product. Group I: Permanent denture bases fabricated with heat polymerized Polymethylmethacrylate resin. Group II: Group I permanent denture bases with wax rims reprocessed with heat polymerized Polymethylmethacrylate resin. Both the group were evaluated for fit using a travelling microscope. Results: Statistical analysis revealed that at each measurement period the mean posterior palatal border openings were not significantly different for processed and reprocessed denture bases. (p >0.05). Discussion: Reprocessing permanent denture base under controlled laboratory conditions without significant dimensional change, will encourage the clinicians to use permanent record base during jaw relations and try-in. Conclusion: Maxillary permanent complete denture bases were not found to distort significantly as a result of first and second curing cycle. The central part of the posterior palatal border of the denture showed the greatest discrepancy, which was as less as 0.11 to 0.13mm. Reprocessing the permanent complete denture base in controlled laboratory conditions will not affect the fit and adaptation.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom