A Novel Repair Technique for the Internal Thermal Control System Dual-Membrane Gas Trap
Author(s) -
Thomas O. Leimkuehler,
Vipul Patel,
Daniel R. Reeves,
James M. Holt
Publication year - 2005
Publication title -
sae technical papers on cd-rom/sae technical paper series
Language(s) - English
Resource type - Conference proceedings
SCImago Journal Rank - 0.295
H-Index - 107
eISSN - 1083-4958
pISSN - 0148-7191
DOI - 10.4271/2005-01-3079
Subject(s) - trap (plumbing) , dual (grammatical number) , thermal , materials science , computer science , environmental science , physics , thermodynamics , art , literature , environmental engineering
A dual-membrane gas trap is currently used to remove gas bubbles from the Internal Thermal Control System (ITCS) coolant on board the International Space Station (ISS). The gas trap consists of concentric tube membrane pairs, comprised of outer hydrophilic tubes and inner hydrophobic fibers. Liquid coolant passes through the outer hydrophilic membrane, which traps the gas bubbles. The inner hydrophobic fiber allows the trapped gas bubbles to pass through and vent to the ambient atmosphere in the cabin. The gas trap was designed to last for the entire lifetime of the ISS, and therefore was not designed to be repaired. However, repair of these gas traps is now a necessity due to contamination from the on-orbit ITCS fluid and other sources on the ground as well as a limited supply of flight gas traps. This paper describes a novel repair technique that has been developed that will allow the refurbishment of contaminated gas traps and their return to flight use.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom