Study on Electromagnetic Transient Condition of EMU Passing by Phase-separation with Electric Load in High-speed Railway
Author(s) -
Xiaoxu Guo,
Wei Jian-zhong,
Long Xu,
Shibin Gao,
Zhengqing Han
Publication year - 2013
Publication title -
energy and power engineering
Language(s) - English
Resource type - Journals
eISSN - 1949-243X
pISSN - 1947-3818
DOI - 10.4236/epe.2013.54b202
Subject(s) - transient (computer programming) , separation (statistics) , electrical engineering , materials science , phase (matter) , automotive engineering , mechanics , engineering , mechanical engineering , physics , computer science , operating system , quantum mechanics , machine learning
Aiming at the complex electromagnetic transient process of EMU passing by phase-separation with electric load in high-speed railway, mechanism of overvoltage caused by switching off, overvoltage caused by switching on and impact current is analyzed systematically in this article. π-type equivalent circuit of feeding section is put forward in the analysis of overvoltage mechanism. Overvoltage and overcurrent model of passing by phase-separation with electric load are also built. Correctness of mechanism was validated by simulation. In addition, the methods to solve the influence on substations, transformers and protection devices in this process are put forward, which provides a new idea on passing by phase-separation with electric load technology.