Validation of A Point-of-Care Lactate Device For Screening At-Risk Adults Receiving Combination Antiretroviral Therapy In Botswana
Author(s) -
Sikhulile Moyo,
Hermann Bussmann,
Phibeon Munyaradzi Mangwendeza
Publication year - 2011
Publication title -
journal of antivirals and antiretrovirals
Language(s) - English
Resource type - Journals
ISSN - 1948-5964
DOI - 10.4172/jaa.1000034
Subject(s) - lactic acidosis , medicine , point of care , cart , lactic acid , pathology , biology , mechanical engineering , bacteria , engineering , genetics
BACKGROUND: Nucleoside reverse-transcriptase inhibitors (NRTIs) are a major component of combination antiretroviral therapy (cART) worldwide but they have been associated with mitochondrial toxicities, with one of the most significant being lactic acidosis. In southern Africa, being female and overweight (BMI > 25) as well as receiving d4T and/or ddI-based cART are risk factors for the development of this potentially life-threatening complication. It is challenging in many resource-limited settings to obtain reliable serum lactate measurements while screening for the presence of lactic acidosis. Point-of-care devices, however, are now available that provide simple, accurate measurements of serum lactate levels at relatively low cost. The objective of this study was to assess the agreement of the portable (Accutrend™ handheld) lactate analyzer to the conventional laboratory system for obtaining serum lactate. METHODS: Eighty two "at-risk" cART-treated adults were evaluated, having their lactate levels tested in parallel using both modalities. RESULTS: The mean (range) lactate level for the portable device was 2.28 (0.9-5.0) compared to 1.96 (0.7-5.4) using the conventional method. There was a strong correlation (p<0.05) between the portable device and the conventional means with a Pearson correlation coefficient of 0.92 [95% CI: 0.88-0.95]. The mean bias was 0.33 [95% CI: -0.39-1.04], with the portable device having slightly higher values. CONCLUSION: The use of a portable lactate device provides an accurate and user-friendly means of screening at-risk patients for the presence of lactic acidosis in resource-limited settings with limited laboratory capacity.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom