z-logo
open-access-imgOpen Access
Fully Covered Self Expandable Metal Stent for the Treatment of Benign Biliary Strictures
Author(s) -
Jae Uk Shin,
Kyu Taek Lee
Publication year - 2012
Publication title -
korean journal of gastroenterology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.203
H-Index - 25
eISSN - 2233-6869
pISSN - 1598-9992
DOI - 10.4166/kjg.2012.59.1.58
Subject(s) - medicine , stent , entecavir , gastroenterology , tacrolimus , general surgery , chronic hepatitis , virus , transplantation , virology , lamivudine
: , 135-710, 50, Correspondence to: Kyu Taek Lee, Division of Gastroenterology, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50 Irwon-dong, Gangnam-gu, Seoul 135-710, Korea. Tel: +82-2-3410-3409, Fax: +82-2-3410-6983, E-mail: happymap@skku.edu Financial support: None. Conflict of interest: None. : B 1 45 . , . . tacrolimus 4 mg bid, mycophenolate 500 mg bid , B entecavir 0.5 mg qd, aspirin 100 mg qd . 5.2 mg/dL, 3.4 mg/dL, AST 371 IU/L, ALT 548 IU/L, ALP 1,462 IU/L, GGT 1,255 U/L, 204 mg/dL . , , . (Fig. 1A) (6 mm 11 atm 1 ) , 6 mm, 12 cm (Fig. 1B, D, E). (anastomosis site) , 6 mm , (self-expandable metal stent) (Fig. 2). , 3 . , (Fig. 1C, F). .