Standardization of Gene Expression Quantification by Absolute Real-Time qRT-PCR System Using a Single Standard for Marker and Reference Genes
Author(s) -
Yi-Hong Zhou,
Vinay Raj,
Eric R. Siegel,
Liping Yu
Publication year - 2010
Publication title -
biomarker insights
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.075
H-Index - 31
ISSN - 1177-2719
DOI - 10.4137/bmi.s5596
Subject(s) - reference genes , gene , real time polymerase chain reaction , gene expression , computational biology , gene expression profiling , dna microarray , biology , genetics , bioinformatics
In the last decade, genome-wide gene expression data has been collected from a large number of cancer specimens. In many studies utilizing either microarray-based or knowledge-based gene expression profiling, both the validation of candidate genes and the identification and inclusion of biomarkers in prognosis-modeling has employed real-time quantitative PCR on reverse transcribed mRNA (qRT-PCR) because of its inherent sensitivity and quantitative nature. In qRT-PCR data analysis, an internal reference gene is used to normalize the variation in input sample quantity. The relative quantification method used in current real-time qRT-PCR analysis fails to ensure data comparability pivotal in identification of prognostic biomarkers. By employing an absolute qRT-PCR system that uses a single standard for marker and reference genes (SSMR) to achieve absolute quantification, we showed that the normalized gene expression data is comparable and independent of variations in the quantities of sample as well as the standard used for generating standard curves. We compared two sets of normalized gene expression data with same histological diagnosis of brain tumor from two labs using relative and absolute real-time qRT-PCR. Base-10 logarithms of the gene expression ratio relative to ACTB were evaluated for statistical equivalence between tumors processed by two different labs. The results showed an approximate comparability for normalized gene expression quantified using a SSMR-based qRT-PCR. Incomparable results were seen for the gene expression data using relative real-time qRT-PCR, due to inequality in molar concentration of two standards for marker and reference genes. Overall results show that SSMR-based real-time qRT-PCR ensures comparability of gene expression data much needed in establishment of prognostic/predictive models for cancer patients-a process that requires large sample sizes by combining independent sets of data.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom