z-logo
open-access-imgOpen Access
Development and Validation of a HPLC Method to Determine Griseofulvin in Rat Plasma: Application to Pharmacokinetic Studies
Author(s) -
Bo Wei,
Dong Liang,
Theodore R. Bates
Publication year - 2008
Publication title -
analytical chemistry insights
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.406
H-Index - 17
ISSN - 1177-3901
DOI - 10.4137/aci.s953
Subject(s) - griseofulvin , chromatography , high performance liquid chromatography , pharmacokinetics , detection limit , coefficient of variation , extraction (chemistry) , acetonitrile , aqueous solution , dilution , bioanalysis , chemistry , medicine , pharmacology , physics , pathology , thermodynamics
A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5) to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C(18) reversed phase column (4.6 x 150 mm, 3.5 microm), using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5) delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (lambda(excitation) = 300 nm, lambda(emission) = 418 nm). The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error) were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation) was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD) and the limit of quantification (LOQ) of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom