Liquid Chromatography with Post-Column Reagent Addition of Ammonia in Methanol Coupled to Negative Ion Electrospray Ionization Tandem Mass Spectrometry for Determination of Phenoxyacid Herbicides and their Degradation Products in Surface Water
Author(s) -
Renata Raina,
Michele L. Etter
Publication year - 2010
Publication title -
analytical chemistry insights
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.406
H-Index - 17
ISSN - 1177-3901
DOI - 10.4137/aci.s3148
Subject(s) - chromatography , chemistry , selected reaction monitoring , acetic acid , electrospray ionization , formic acid , liquid chromatography–mass spectrometry , ammonium acetate , methanol , tandem mass spectrometry , solid phase extraction , ion chromatography , mass spectrometry , reagent , high performance liquid chromatography , organic chemistry
A new liquid chromatography (LC)-negative ion electrospray ionization (ESI(-))-tandem mass spectrometry (MS/MS) method with post-column addition of ammonia in methanol has been developed for the analysis of acid herbicides: 2,4-dichlorophenoxy acetic acid, 4-chloro-o-tolyloxyacetic acid, 2-(2-methyl-4-chlorophenoxy)butyric acid, mecoprop, dichlorprop, 4-(2,4-dichlorophenoxy) butyric acid, 2,4,5-trichlorophenoxy propionic acid, dicamba and bromoxynil, along with their degradation products: 4-chloro-2-methylphenol, 2,4-dichlorophenol, 2,4,5-trichlorophenol and 3,5-dibromo-4-hydroxybenzoic acid. The samples were extracted from the surface water matrix using solid-phase extraction (SPE) with a polymeric sorbent and analyzed with LC ESI(-) with selected reaction monitoring (SRM) using a three-point confirmation approach. Chromatography was performed on a Zorbax Eclipse XDB-C18 (50 x 4.6 mm i.d., 1.8 mum) with a gradient elution using water-methanol with 2 mM ammonium acetate mobile phase at a flow rate of 0.15 mL/min. Ammonia in methanol (0.8 M) was added post-column at a flow rate of 0.05 mL/min to enhance ionization of the degradation products in the MS source. One SRM transition was used for quantitative analysis while the second SRM along with the ratio of SRM1/SRM2 within the relative standard deviation determined by standards for each individual pesticide and retention time match were used for confirmation. The standard deviation of ratio of SRM1/SRM2 obtained from standards run on the day of analysis for different phenoxyacid herbicides ranged from 3.9 to 18.5%. Limits of detection (LOD) were between 1 and 15 ng L(-1) and method detection limits (MDL) with strict criteria requiring <25% deviation of peak area from best-fit line for both SRM1 and SRM2 ranged from 5 to 10 ng L(-1) for acid ingredients (except dicamba at 30 ng L(-1)) and from 2 to 30 ng L(-1) for degradation products. The SPE-LC-ESI(-) MS/MS method permitted low nanogram-per-liter determination of pesticides and degradation products for surface water samples.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom