The accuracy of multi-slice three-dimensional computerized tomography on the verification of the pedicle screw trajectory
Author(s) -
Suat Erol Çelik,
Bilal Kelten,
Recai Gökcan,
Ahmet Cevri Yildiz
Publication year - 2009
Publication title -
orthopedic reviews
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.412
H-Index - 13
eISSN - 2035-8237
pISSN - 2035-8164
DOI - 10.4081/or.2009.e22
Subject(s) - medicine , tomography , multislice , radiology , nuclear medicine , computed tomography
The purpose of our study was to determine the diagnostic power of three-dimensional reformatted multi-slice computerized tomography (CT) images on misplaced pedicle screws in spinal surgery. Eighty-four consecutive patients with 458 screws in situ were investigated prospectively using both axial CT slices and reformatted images after operation by two blinded investigators. All the screw misplacements were documented and the differences between the two imaging modalities were recorded. Axial CT slices were able to show only 23 of 60 misplaced pedicle screws; multi-slice CT was three times more powerful in the diagnosis of pedicle screw complications in spinal surgery (p<0.05). We concluded that multi-slice CT reconstruction should be the primary diagnostic tool after screw implantation in the human spine