z-logo
open-access-imgOpen Access
Management of Peritoneal Dialysis Catheters that Erode into Bowel: Two Pediatric Case Reports and a Review of the Literature
Author(s) -
Markel Troy A.,
West Karen W.
Publication year - 2016
Publication title -
peritoneal dialysis international
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.79
H-Index - 83
eISSN - 1718-4304
pISSN - 0896-8608
DOI - 10.3747/pdi.2016.00029
Subject(s) - medicine , peritoneal dialysis , peritonitis , complication , catheter , surgery , limiting , dialysis , mechanical engineering , engineering
Erosion of peritoneal dialysis (PD) catheters into the intestine is a rare complication of PD. Herein, we convey the first reports of 2 pediatric patients undergoing PD who were found to have the catheter eroding into their intestines. They were treated minimally with catheter removal and antibiotics. Definitive repair of the intestinal injury was not performed. These are the first pediatric patients reported with PD catheter erosion. Perforating injuries may be self-limiting, and therefore a more minimal approach may be considered in certain patient populations who do not express overt signs of peritonitis or illness.