z-logo
open-access-imgOpen Access
The Effect of Dental Implant Length and Diameter on the Stress Distribution at the Implant-Bone Interface of the Immediate Loading Implants: A 3/D Finite Element Analysis
Author(s) -
Talal Mohamad,
Umer Al-Adel,
Eissa Wahbeh
Publication year - 2012
Publication title -
˜al-œrafidain dental journal/maǧallaẗ al-rāfidayn li-ṭibb al-asnān
Language(s) - English
Resource type - Journals
eISSN - 1998-0345
pISSN - 1812-1217
DOI - 10.33899/rden.2012.84678
Subject(s) - implant , materials science , finite element method , stress (linguistics) , dental implant , stress concentration , dentistry , biomedical engineering , composite material , structural engineering , medicine , surgery , fracture mechanics , engineering , linguistics , philosophy
Aims: to evaluate the effect of implant length and diameter on the values and distribution of stresses of immediate loading implants by using three-dimensional (3D) finite elements (FE) analysis. Materials and Method: A 3-D FE model of an implant embedded in a block of bone was used in this study. The implant was LEADER/ ITALIA-Fix type which is specially designed for immediate loading. ANSYS V.12 program was used to build solid model of the implant and bone, and performing the finite element analysis. Two lengths of implant were used (11mm. and 13mm)., and two diameters (3.75mm. and 4.25mm.). Results: The results showed that the areas of maximum stress of all lengths and diameters are located at the neck of implants, the increase in the implant length from 11mm. to 13mm. leading to slightly increase in the stress at the implant-bone interface, while the increase in the diameter from 3.75mm. to 4.25mm. having no significant effect in increasing the value of stresses around dental implants. Conclusions: The increase in the implant length is negatively affect on stress values, but it leads to better dissipation of stresses around dental implant. The increase in the diameter having no obvious effect on stress values. However, it reduce the area of maximum stress at the implant neck. Key wards: immediate loading implants, implant length, implant diameter, finite element analysis. Mohamad TH, Al-Adel U, Wahbeh E. The Effect of Dental Implant Length and Diameter on the Stress Distribution at the Implant-Bone Interface of the Immediate Loading Implants: A 3/D Finite Element Analysis. Al–Rafidain Dent J. 2013; 13(1): 44-51. Received: 22/5/2011 Sent to Referees: 30/5/2011 Accepted for Publication: 18/7/201

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom