Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy
Author(s) -
Philip A. Starr,
Alastair J. Martin,
Jill L. Ostrem,
Pekka Talke,
Nadja Levesque,
Paul Larson
Publication year - 2010
Publication title -
journal of neurosurgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.564
H-Index - 210
eISSN - 1933-0693
pISSN - 0022-3085
DOI - 10.3171/2009.6.jns081161
Subject(s) - deep brain stimulation , subthalamic nucleus , medicine , posterior commissure , stereotaxy , magnetic resonance imaging , nuclear medicine , stereotaxis , parkinson's disease , biomedical engineering , radiology , computer science , artificial intelligence , disease , nucleus , pathology , psychiatry , haptic technology
Object The authors discuss their method for placement of deep brain stimulation (DBS) electrodes using interventional MR (iMR) imaging and report on the accuracy of the technique, its initial clinical efficacy, and associated complications in a consecutive series of subthalamic nucleus (STN) DBS implants to treat Parkinson disease (PD). Methods A skull-mounted aiming device (Medtronic NexFrame) was used in conjunction with real-time MR imaging (Philips Intera 1.5T). Preoperative imaging, DBS implantation, and postimplantation MR imaging were integrated into a single procedure performed with the patient in a state of general anesthesia. Accuracy of implantation was assessed using 2 types of measurements: the “radial error,” defined as the scalar distance between the location of the intended target and the actual location of the guidance sheath in the axial plane 4 mm inferior to the commissures, and the “tip error,” defined as the vector distance between the expected anterior commissure–posterior commissure (AC-PC) coordinates of the permanent DBS lead tip and the actual AC-PC coordinates of the lead tip. Clinical outcome was assessed using the Unified Parkinson's Disease Rating Scale part III (UPDRS III), in the off-medication state. Results Twenty-nine patients with PD underwent iMR imaging–guided placement of 53 DBS electrodes into the STN. The mean (± SD) radial error was 1.2 ± 0.65 mm, and the mean absolute tip error was 2.2 ± 0.92 mm. The tip error was significantly smaller than for STN DBS electrodes implanted using traditional frame-based stereotaxy (3.1 ± 1.41 mm). Eighty-seven percent of leads were placed with a single brain penetration. No hematomas were visible on MR images. Two device infections occurred early in the series. In bilaterally implanted patients, the mean improvement on the UPDRS III at 9 months postimplantation was 60%. Conclusions The authors' technical approach to placement of DBS electrodes adapts the procedure to a standard configuration 1.5-T diagnostic MR imaging scanner in a radiology suite. This method simplifies DBS implantation by eliminating the use of the traditional stereotactic frame and the subsequent requirement for registration of the brain in stereotactic space and the need for physiological recording and patient cooperation. This method has improved accuracy compared with that of anatomical guidance using standard frame-based stereotaxy in conjunction with preoperative MR imaging.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here