z-logo
open-access-imgOpen Access
Bicentric Bipolar Prosthesis in Non-Traumatic Hip Pathologies: Maximum 10 Years Follow Up
Author(s) -
Subash C. Jha,
Anıl Kumar,
Prakash Shakya
Publication year - 2018
Publication title -
birat journal of health sciences
Language(s) - English
Resource type - Journals
eISSN - 2542-2804
pISSN - 2542-2758
DOI - 10.3126/bjhs.v2i3.18934
Subject(s) - medicine , prosthesis , avascular necrosis , acetabulum , surgery , harris hip score , ankylosing spondylitis , radiological weapon , arthroplasty , rheumatoid arthritis , osteoarthritis , femoral head , alternative medicine , pathology
Introduction of bipolar prosthesis was basically made for the treatment of fresh fracture neck of femur in elderly, but with advancement in design and techniques its use has been increased to various non-traumatic hip pathologies.Objective: To assess clinical and radiological outcome of BHU bicentric bipolar hip prosthesis in treatment of non-traumatic hip pathology.Methodology: This longitudinal study was done in 30 cases of various hip conditions, during the period of March 2002 to March 2012. All patients had secondary osteoarthritis of hip with abnormal acetabulum following advanced tubercular arthritis, rheumatoid arthritis, ankylosing spondylitis and avascular necrosis of femoral head. Primary bipolar hemi-replacement arthroplasty was done in all the cases using Banaras Hindu University (BHU) bicentric bipolar hip prosthesis. Each patient was assessed radiologically for movement and fraction of it occurring at various components of prosthesis and clinically for functional outcome using modified Harris hip score for the maximum of 10 years.Results: There were 17 males and 13 females (n=30), aged between 31-60 years. Three and half years following surgery, (n=12) 100% patients were able to squat and sit crossed legged. At four and half years follow-up, (n=7) 100% patient had excellent result when assessed by modified Harris hip score. Radiologically, by the end of 10 years (n=1) all the movements of hip occurred at inner bearing while the outer bearing was fixed to acetabulum.Conclusion: This intermediate term follow-up study suggests that the use of BHU bicentric bipolar hip prosthesis for bipolar hemireplacement is associated with be

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom