z-logo
open-access-imgOpen Access
Borg’s category ratio-scale (CR-10) is useful to predict the onset of blood lactate accumulation (OBLA) in young Mexicans adults, regardless their body mass
Author(s) -
Arnulfo RamosJiménez,
Abraham WallMedrano,
Marco Antonio Hernández-Lepe,
Gregorio Chávez Treviño,
Jaime Guereca Arvizuo,
Rosa Patricia Hernández Torres
Publication year - 2019
Publication title -
ciencia ergo sum
Language(s) - Spanish
Resource type - Journals
eISSN - 2395-8782
pISSN - 1405-0269
DOI - 10.30878/ces.v26n1a7
Subject(s) - blood lactate , regression analysis , heart rate , analysis of variance , body mass index , medicine , zoology , blood pressure , mathematics , statistics , biology
espanolObjetivo: evaluar el valor predictivo de la escala de Borg (CR-10; 1-10) para el inicio de la acumulacion de lactato en sangre (OBLA). Metodos: 91 jovenes mexicanos realizaron tres pruebas de ejercicio submaximas no consecutivas. La frecuencia cardiaca (FC), el lactato en sangre y el consumo de oxigeno se registraron en cada determinacion del CR-10. Se calcularon ecuaciones de regresion y los puntos de corte de FC y al OBLA. Resultados: La FC (86 lat/min) y el CR-10 (4.5) predijeron el OBLA con la misma certeza, independientemente de la masa corporal del sujeto. CR-10, la FC y el consumo de oxigeno explicaron independientemente mas de 60% de la varianza asociada al OBLA. Conclusiones: CR-10 es util para predecir el OBLA con casi la misma certeza que la FC, independientemente de la masa corporal del sujeto. EnglishAim: To evaluate the predictive value of Borg’s category ratio-scale (CR-10; 1-10) toward the onset of blood lactate accumulation (OBLA). Methods: 91 young Mexicans performed three non-consecutive sub-maximal exercise tests. Heart rate (HR), blood lactate and oxygen uptake were recorded at each CR-10 rating. Regression equations, reliable HR and CR-10 cut-off points of OBLA were then calculated. Results: HR (86 beats/min) and CR-10 (4.5) predicted OBLA with the same certainty, regardless the subject’s body mass. CR-10, HR and oxygen uptake, independently explained more than 60% of the associated variance to OBLA. Conclusions: CR-10 is useful to predict OBLA with almost the same certainty that HR, regardless the subject’s body mass.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom