z-logo
open-access-imgOpen Access
Projeto experimental de uma placa de condicionamento de sinal para um sensor de corrente diferencial tipo Bobina de Rogowski
Author(s) -
Débora Debiaze de Paula,
Andreyna Sárila Ramos Ferreira,
Paulo Jefferson Dias de Oliveira Evald,
Cláudio Dornelles Mello Júnior,
Rodrigo Zelir Azzolin
Publication year - 2020
Publication title -
forscience
Language(s) - Portuguese
Resource type - Journals
eISSN - 2318-6356
pISSN - 2318-6097
DOI - 10.29069/forscience.2020v8n2.e797
Subject(s) - rogowski coil , physics , humanities , electrical engineering , current (fluid) , engineering , art , thermodynamics
Realizar a medicao de grandezas fisicas, tais como corrente e tensao, com precisao e de fundamental importância na area da instrumentacao para automacao, visto que tais medicoes geralmente realimentam controladores em malha fechada. De modo geral, os sinais aquisitados sao de baixa intensidade. Assim, e indispensavel o uso de placas de condicionamento de sinal para converter a grandeza medida em uma forma adequada aos sistemas de processamento de dados e controle. Dessa forma, a principal contribuicao deste trabalho e apresentar uma metodologia para elaboracao de um sistema de condicionamento de sinais para leitura de corrente, por meio de um sensor do tipo Bobina de Rogowski. Assim, espera-se que, como resultado deste trabalho, qualquer pessoa consiga reproduzir o sistema de medicao bem como as placas de circuito impresso apresentadas neste documento para a correta medicao de corrente. Alem disso, tambem sao apresentados, de forma didatica, os passos matematicos que atendam as especificacoes do projeto de instrumentacao proposto.Palavras-chave: Condicionamento de sinal. Bobina de Rogowski. Medicao de corrente. Instrumentacao. Experimental project of a signal conditioning plate for a Rogowski coil differential current sensorAbstractMeasurement of physical quantities, such as current and voltage, with precision is of fundamental importance in the area of instrumentation for automation, since such measurements generally feedback closed loop controllers. In general, the signals acquired have low intensity. Thus, it is essential to use signal conditioning plates to convert the measured quantity into a form suitable for data processing and control systems. Thus, the main contribution of this work is to present a methodology for the elaboration of a signal conditioning system for current reading, in a didactic way. It is expected that, as a result of this work, anyone can reproduce the measurement system, as well as the printed circuit boards presented in this document for correct current measurement. In addition, the mathematical steps that meet the specifications of the proposed instrumentation project are also presented in a didactic way.Keywords: Signal conditioning. Rogowski coil. Current measurement. Instrumentation.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom