z-logo
open-access-imgOpen Access
The accuracy of computer-aided design and manufacturing surgical-guide for infrazygomatic crest miniscrew placement
Author(s) -
Prajak Jariyapongpaiboon,
Jirawan Chartpitak,
Jaturong Jitsaard
Publication year - 2021
Publication title -
apos trends in orthodontics
Language(s) - English
Resource type - Journals
eISSN - 2321-4600
pISSN - 2321-1407
DOI - 10.25259/apos_127_2020
Subject(s) - coronal plane , sagittal plane , crest , cone beam computed tomography , medicine , orthodontics , alveolar crest , cad , absolute deviation , computer science , computed tomography , surgery , mathematics , dental alveolus , anatomy , engineering drawing , physics , statistics , quantum mechanics , engineering
Objectives: Infrazygomatic crest (IZC) surgical guides have been employed to prevent any avoidable complications during miniscrew insertion. The purpose of this study was to evaluate the accuracy of IZC miniscrew placement when using a surgical-guide developed by computer-aided design and manufacturing (CAD/CAM) techniques. Materials and Methods: Ten patients were scanned with cone-beam computed tomography for three-dimensional (3D) planning of IZC miniscrew placements. The upper arches were scanned separately, and virtual miniscrews were placed in the position planned by 3D software. The CAD/CAM surgical guides were designed and fabricated individually to enable accurate miniscrew placement. Subsequently, 20 self-drilling miniscrews were inserted at the right and left IZC areas using 5 CAD/CAM surgical guides (CS group, n = 10) and direct insertion (DI group, n = 10), respectively. Pre- and post-operative digital model images were compared, actual and planned miniscrew positions were superimposed and measured for 3D angular and distance deviations in the two groups. Comparisons between groups were made using the Kruskal–Wallis test. Results: In the CS group, the median coronal and sagittal angular deviations were 2.95 degrees (range 0.34–5.26 degrees) and 2.05 degrees (range 0.38–4.08 degrees), respectively, while the median coronal and apical deviations were 0.39 mm (range 0.24–0.51 mm) and 0.50 mm (range 0.16–0.66 mm). These deviations differed significantly from those of the DI group. Conclusion: The IZC CAD/CAM surgical guide has made it possible to control miniscrew placement with high precision.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom