Subject(s) - set point , controller (irrigation) , swift , control theory (sociology) , materials science , thermal , environmental science , analytical chemistry (journal) , mechanics , chemistry , physics , thermodynamics , engineering , computer science , biology , astrophysics , control engineering , control (management) , chromatography , artificial intelligence , agronomy
The Swift BAT LHP #0 primary heater controller failed on March 31, 2010. It has been disabled. On October 31, 2015, the secondary heater controller of this LHP failed. On November 1, 2015, the LHP #0 CC temperature increased to as 18.6 C, despite that the secondary heater controller set point was 8.8 C. It caused the average DM XA1 temperature to increase to 25.9 C, which was 5 C warmer than nominal. As a result, the detectors became noisy. To solve this problem, the LHP #1 secondary heater controller set point was decreased in 0.5 C decrements to 2.2 C. The set-point decrease restored the average DM XA1 temperature to a nominal value of 19.7 C on November 21.