Experiment-to-experiment disturbance of microgravity environment
Author(s) -
Richard DeLombard,
Kenneth Hrovat,
Kevin McPherson
Publication year - 1999
Publication title -
38th aerospace sciences meeting and exhibit
Language(s) - English
Resource type - Conference proceedings
DOI - 10.2514/6.1999-576
Subject(s) - disturbance (geology) , aeronautics , weightlessness , computer science , aerospace engineering , environmental science , engineering , physics , geology , paleontology , astronomy
The STS-87 Shuttle mission carried the Fourth United States MicroGravity Payload (USMP-4) as one of the primary payloads. Four USMP-4 science experiments were installed on two carriers in the cargo bay of the Shuttle. The Confined Helium Experiment (CHeX), located on the aft carrier, was particularly susceptible to vibrations in several frequency ranges due to structural resonances of the CHeX apparatus and the extreme sensitivity of the sample to vibrations. Shortly after activation of the USMP-4 payload, a strong, vibratory disturbance within the susceptibility region of the CHeX apparatus was detected. After investigating the characteristics of the disturbance and the time at which it first appeared, it was deduced that the vibration was generated by cooling fans in the Isothermal Dendritic Growth Experiment (IDGE). This paper will summarize the development of the conflict, briefly describe the disturbance source, and the susceptibility of the CHeX apparatus, and summarize the results of post-mission tests of IDGE.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom