Electroanalytical determination of metronidazole in tablet dosage form
Author(s) -
Selehattin Yılmaz,
Esra Baltaoglu,
Gulsen Saglikoglu,
Sultan Yağmur,
Kamran Polat,
Murat Sadıkoğlu
Publication year - 2012
Publication title -
journal of the serbian chemical society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.227
H-Index - 45
eISSN - 1820-7421
pISSN - 0352-5139
DOI - 10.2298/jsc120111069y
Subject(s) - metronidazole , dosage form , chemistry , chromatography , pharmacology , medicine , antibiotics , biochemistry
In this study, the electrochemical reduction and determination of metronidazole were easily realized in Britton-Robinson buffer (pH = 4.01) using UTGE by cyclic voltammetric (CV) and differential pulse voltammetric (DPV) techniques. In this acidic medium, one irreversible and sharp cathodic peak was observed. A linear calibration curve for DPV analysis was constructed in the metronidazole concentration range 3x10-6 - 9x 10-5 mol L-1. Limit of detection (LOD) and limit of quantification (LOQ) were 1.42x10-7 and 4.76x10-7 mol L-1 respectively