Subject(s) - phenylephrine , medicine , bispectral index , anesthesia , cardiac index , propofol , hemodynamics , vascular resistance , stroke volume , blood pressure , mean arterial pressure , abdominal surgery , cardiac output , heart rate , surgery
Background. We studied the effects of a parallel phenylephrine infusion during bispectral index guided anaesthesia in-duction with propofol on haemodynamic parameters. We hypothesised that mean ar-terial pressure and cardiac index would be better maintained in the group of patients receiving the phenylephrine infusion dur-ing induction.Methods. We studied ASA I-III patients scheduled for oncological abdominal sur-gery. Forty patients randomly received ei-ther a 0.9% NaCl or a phenylephrine (0.5 μg/kg/min) infusion during the induction of anaesthesia with propofol to a bispectral index value of 60. Mean arterial pressure, stroke volume index and systemic vascular resistance index were recorded, starting at one minute before induction for 20 min-utes, at one-minute intervals.Results. After induction of anaesthesia before intubation mean arterial pressure and stroke volume index decreased sig-nificantly compared to baseline in both groups, while the systemic vascular resist-ance index increased slightly. At the end of measurements, mean arterial pressure (66 ± 11 vs. 94 ± 14 mmHg; 0.9% NaCl vs. phenylephrine group p<0.01) and stroke volume index (34.2 ± 9.1 vs. 44.0 ± 9.7 ml/m2; 0.9% NaCl vs. phenylephrine group p<0.01) were lower in both groups in com-parison to baseline values, but were better maintained in the phenylephrine group, whereas systemic vascular resistance index was higher than at baseline (2308 ± 656 vs. 3198 ± 825 dynes s/cm5/m2; 0.9% NaCl vs. phenylephrine group p<0.01) with signifi-cant differences between groups. Conclusion. Our study shows that a con-tinuous phenylephrine infusion can atten-uate the drop in mean arterial pressure and stroke volume index during anaesthesia induction with propofol.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom