z-logo
open-access-imgOpen Access
A novel device for intraoperative photodynamic therapy dedicated to glioblastoma treatment
Author(s) -
Clément Dupont,
Serge Mordon,
Pascal Deleporte,
Nicolas Reyns,
Maximilien Vermandel
Publication year - 2017
Publication title -
future oncology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.857
H-Index - 72
eISSN - 1744-8301
pISSN - 1479-6694
DOI - 10.2217/fon-2017-0261
Subject(s) - medicine , photodynamic therapy , glioblastoma , medical physics , cancer research , organic chemistry , chemistry
International audienceAIM:Photodynamic therapy (PDT) appears to be a valuable new treatment modality for cancer therapy. Studies have reported successful application of PDT for glioblastoma. Here, we introduce a new device dedicated to intraoperative PDT delivered early after fluoro-guided resection combined with a transfer function that determines the treatment time based on the size of the surgical resection cavity.MATERIALS & METHODS:First, we describe the device, which is composed of a trocar, a balloon filled with a diffusing solution, and a fiber guide in which a cylindrical light diffuser is inserted. Ex vivo experiments were performed to measure the fluence rate inside biological tissues. A calibration factor was defined to convert power measurements into fluence rate values. Calf brains were used to simulate light propagation in human brain tissue, and the photosensitizer administration effect on optical properties was discussed. The temperature elevation during illumination was evaluated.RESULTS:Light power was measured in tissues surrounding the device during ex vivo experiments. Using the previously characterized calibration factor, power measurements were converted to fluence rate values to obtain the transfer function. No thermal elevation was observed during a 2-h temperature test, and the impact of protoporphyrin IX on brain optical properties was considered negligible.CONCLUSION:A discussion of experimental precision is presented. The light duration determined by the abacus had a standard deviation of <1 min. This value is weak compared with the total illumination time necessary to treat one patient. The main advantage of our device lies in its straightforward implementation of intraoperative PDT for neurosurgery with acceptable dosimetry and easy treatment time

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom