z-logo
open-access-imgOpen Access
Vapor space characterization of waste tank 241-C-109: Results from samples collected on 8/10/94
Author(s) -
K.H. Pool,
T.W. Clauss,
M.W. Ligotke
Publication year - 1995
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/93749
Subject(s) - sorbent , environmental science , hanford site , waste management , sampling (signal processing) , chemistry , radioactive waste , engineering , adsorption , electrical engineering , organic chemistry , filter (signal processing)
This report describes results of the analyses of tank-headspace samples taken from the Hanford waste Tank 241-C-109 (referred to as Tank C-109). Pacific Northwest Laboratory (PNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and to analyze inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The sample job was designated S4053, and samples were collected by WHC on August 10, 1994, using the vapor sampling system (VSS). Sampling devices, including six sorbent trains (for inorganic analyses) and five SUMMA{sup {trademark}} canisters (for organic analyses) were supplied to the WHC sampling staff on August 8. Samples were taken (by WHC) from the tank headspace on August 10 and were returned to PNL from the field on August 12. The samples were inspected upon delivery to the 326/23B laboratory and logged into PNL record book 55408 before implementation of PNL Technical Procedure PNL-TVP-07. Custody of the sorbent traps was transferred to PNL personnel performing the inorganic analysis and stored at refrigerated ({<=}10{degrees}C) temperature until the time of analysis. The canister was stored in the 326/23B laboratory at ambient (25{degrees}C) temperature until time of analysis. Access to the 326/23B laboratory is limited to PNL personnel working on the waste-tank safety program. Analyses described in this report were performed at PNL in the 300 area of the Hanford Reservation. Analytical methods that were used are described in the text. In summary, sorbent traps for inorganic analyses containing sample materials were either weighed (for water analysis) or desorbed with the appropriate aqueous solutions (for ammonia (NH{sub 3}) or nitrite (NO{sub 2}) analyses). The aqueous extracts were analyzed either by selective electrode or by ion chromatography (IC). Organic analyses were performed using cryogenic preconcentration followed by gas chromatography/mass spectrometry (GC/MS)

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom