TANK 241-AN-102 MULTI-PROBE CORROSION MONITORING SYSTEM PROJECT LESSONS LEARNED
Author(s) -
Thomas W. Taylor,
Alan R. Hagensen,
Kirch Nw
Publication year - 2008
Language(s) - English
Resource type - Reports
DOI - 10.2172/934868
Subject(s) - corrosion , software deployment , rack , corrosion monitoring , coupon , fabrication , shell (structure) , mechanical engineering , materials science , computer science , engineering , marine engineering , composite material , operating system , medicine , alternative medicine , finance , pathology , economics
During 2007 and 2008, a new Multi-Probe Corrosion Monitoring System (MPCMS) was designed and fabricated for use in double-shell tank 241-AN-102. The system was successfully installed in the tank on May 1, 2008. The 241-AN-102 MPCMS consists of one 'fixed' in-tank probe containing primary and secondary reference electrodes, tank material electrodes, Electrical Resistance (ER) sensors, and stressed and unstressed corrosion coupons. In addition to the fixed probe, the 241-AN-102 MPCMS also contains four standalone coupon racks, or 'removable' probes. Each rack contains stressed and unstressed coupons made of American Society of Testing and Materials A537 CL1 steel, heat-treated to closely match the chemical and mechanical characteristics of the 241-AN-102 tank wall. These coupon racks can be removed periodically to facilitate examination of the attached coupons for corrosion damage. Along the way to successful system deployment and operation, the system design, fabrication, and testing activities presented a number of challenges. This document discusses these challenges and lessons learned, which when applied to future efforts, should improve overall project efficiency

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here