z-logo
open-access-imgOpen Access
Development of Low Maintenance, Field Ruggedized SO3 CEM
Author(s) -
Ashley D. Williamson,
J.D. McCain
Publication year - 2005
Language(s) - English
Resource type - Reports
DOI - 10.2172/903469
Subject(s) - flue gas , particulates , sample (material) , environmental science , field (mathematics) , condensation , continuous monitoring , analytical chemistry (journal) , process engineering , environmental chemistry , chemistry , waste management , meteorology , engineering , geography , operations management , chromatography , mathematics , organic chemistry , pure mathematics
A prototype semi-continuous monitor and associated particulate-free sample extraction probe have been developed for measuring the concentrations of SO{sub 3} and H{sub 2}SO{sub 4} in industrial flue gases. The monitor provides two measurements per hour for concentrations above 1 ppmv. The probe provides the capability of continuous operation while avoiding passing the sample through a layer of particulate and can be used as a probe for conventional controlled condensation measurements of SO{sub 3} and H{sub 2}SO{sub 4} emissions