Advanced Energy-Efficient Filtration: Fan Filter Unit
Author(s) -
Tengfang Xu
Publication year - 2005
Language(s) - English
Resource type - Reports
DOI - 10.2172/891022
Subject(s) - filter (signal processing) , popularity , unit testing , filtration (mathematics) , engineering , incentive , operations management , computer science , operating system , economics , mathematics , statistics , electrical engineering , software , psychology , social psychology , microeconomics
The objective of this project is to provide assistance in development of a standard test procedure for fan-filter units, which are gaining popularity for use in California cleanrooms. In particular, LBNL carried out collaboration with various stakeholders in the industry and took a lead in developing a draft standard method for testing the energy performance of fan-filter units, and provided assistance to California public utility companies by testing the draft method in PG&E's testing facility. Through testing more units in the future with a robust standard method, baseline performance information can be developed for use in possible energy incentive programs