Coupling Correction in the KEK-ATF Using Orbit Response Matrix Analysis
Author(s) -
A. Wolski
Publication year - 2005
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/839922
Subject(s) - thermal emittance , beam emittance , orbit (dynamics) , physics , beam (structure) , coupling (piping) , matrix (chemical analysis) , optics , ray transfer matrix analysis , materials science , engineering , aerospace engineering , metallurgy , composite material
Orbit Response Matrix (ORM) analysis is a technique used to diagnose and correct optics errors in storage rings. We report the results obtained from the use of ORM analysis at the KEK-ATF to reduce the equilibrium vertical emittance. Measurements of the vertical beam size using a laser wire indicate that the vertical emittance was successfully reduced from 12 pm to around 6 pm (at a bunch charge of 7◊109 particles) using ORM analysis.