Process Integration Study of the Decatur HFCS Plant for American Fructose Company, Decatur, AL [Advanced Industrial Heat Pump Applications and Evaluations]
Author(s) -
A Eastwood
Publication year - 1989
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/834788
Subject(s) - heat pump , process integration , pinch analysis , process engineering , work (physics) , process (computing) , engineering , manufacturing engineering , computer science , mechanical engineering , heat exchanger , operating system
This work has carried out in two phases: Phase 1, identification of opportunities for heat pumps in industrial applications and Phase 2; evaluation of heat pumps in industrial applications. In Phase 1, pinch analysis was applied to several industrial sites to identify the best opportunities for heat pumping and other forms of heat integration. In Phase 2, more detailed analyses were undertaken, including the evaluation of a heat pump installed as a recommendation of Phase 1