Subject(s) - drum , seal (emblem) , spark plug , port (circuit theory) , engineering , payload (computing) , ring (chemistry) , waste management , leak , nuclear engineering , electrical engineering , mechanical engineering , computer science , chemistry , environmental engineering , art , computer network , organic chemistry , network packet , visual arts
This procedure provides instructions for assembling the following contact-handled (CH) packaging payloads: - Drum payload assembly - Standard Waste Box (SWB) assembly - Ten-Drum Overpack (TDOP) In addition, this procedure also provides operating instructions for the TRUPACT-II CH waste packaging. This document also provides instructions for performing ICV and OCV preshipment leakage rate tests on the following packaging seals, using a nondestructive helium (He) leak test: - ICV upper main O-ring seal - ICV outer vent port plug O-ring seal - OCV upper main O-ring seal - OCV vent port plug O-ring seal