Availability Analysis of the Ventilation Stack CAM Interlock System
Author(s) -
J. Young
Publication year - 2000
Language(s) - English
Resource type - Reports
DOI - 10.2172/804478
Subject(s) - interlock , stack (abstract data type) , ventilation (architecture) , computer science , reliability engineering , automotive engineering , engineering , mechanical engineering , operating system
Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability