Tank 241-Z-361 Sludge Retrieval and Treatment Alternatives
Author(s) -
B.K. HAMPTON
Publication year - 2000
Language(s) - English
Resource type - Reports
DOI - 10.2172/803650
Subject(s) - waste management , environmental science , plutonium , line (geometry) , engineering , nuclear engineering , marine engineering , environmental engineering , nuclear physics , physics , mathematics , geometry
The Plutonium Finishing Plant (PFP) Tank 241-Z-361 (Z-361) contains legacy sludge resulting from waste discharges from past missions at PFP. A sketch of the tank is shown in Figure 1. In this view various risers and penetrations are shown along with the sludge level depicted by the horizontal line halfway up the tank, and the ground level depicted by the horizontal line above the tank. The HEPA filter installed for breathing is also shown on one of the risers