Safety evaluation of the ITP filter/stripper test runs and quiet time runs using simulant solution. Revision 3
Author(s) -
Mukul Gupta
Publication year - 1994
Language(s) - English
Resource type - Reports
DOI - 10.2172/80341
Subject(s) - agitator , gallon (us) , piping , filter (signal processing) , environmental science , engineering , waste management , mechanical engineering , environmental engineering , electrical engineering , impeller
The purpose is to provide the technical bases for the evaluation of Unreviewed Safety Question for the In-Tank Precipitation (ITP) Filter/Stripper Test Runs (Ref. 7) and Quiet Time Runs Program (described in Section 3.6). The Filter/Stripper Test Runs and Quiet Time Runs program involves a 12,000 gallon feed tank containing an agitator, a 4,000 gallon flush tank, a variable speed pump, associated piping and controls, and equipment within both the Filter and the Stripper Building