SN-268 encasement leak detection ANA-WT-LDSTA-335 acceptance test procedure
Author(s) -
D.W. Vandyke
Publication year - 1999
Language(s) - English
Resource type - Reports
DOI - 10.2172/797719
Subject(s) - cabinet (room) , leak , leak detection , relay , engineering , detector , line (geometry) , test (biology) , computer hardware , computer science , embedded system , electrical engineering , mechanical engineering , physics , mathematics , geology , paleontology , power (physics) , quantum mechanics , environmental engineering , geometry
This document describes the method used to test design criteria for encasement leak detector system installed in 241-AN-A Encasement Line SN-268, located at 200E Tank Farms. This procedure provides instructions for demonstrating that the pit leak detection relay cabinet and intrinsically safe probe circuit is fully operable