HEMISPHERIC CENTER FOR ENVIRONMENTAL TECHNOLOGY
Author(s) -
M A Ebadian
Publication year - 1999
Language(s) - English
Resource type - Reports
DOI - 10.2172/772524
Subject(s) - coolant , diamond , nuclear engineering , inconel , materials science , mechanical engineering , engineering , composite material , alloy
The Princeton Plasma Physics Laboratory (PPPL) demonstration of the diamond wire cutting technology on the surrogate of the Tokamak Fusion Test Reactor (TFTR), Figure 1, was performed from August 23-September 3, 1999. The plated diamond wire, Figure 2, was successful in cutting through all components of the TFTR surrogate including stainless steel, inconel and graphite. The demonstration tested three different void fill materials (mortar with sand, Rheocell-15, and foam) and three cooling systems (water, air, and liquid nitrogen). The optimum combination was determined to be the use of the low-density concrete void fill, Rheocell-15 with an average density of 52 lbs/ft{sup 3}, using a water coolant. However, the liquid nitrogen performed better than expected with only minor problems and was considered to be a successful demonstration of the Bluegrass Concrete Cutting, Inc. proprietary liquid-nitrogen coolant system. Data from the demonstration is being calculated and a summary of the technology demonstration will be included in the October monthly report. An ITSR will be written comparing the diamond wire saw to the plasma arc (baseline) technology. The MTR Chemical Protective Suit, a proprietary new suit from Kimberly Clark, was evaluated from 8/9/99 to 8/12/99 at Beaver, WV. This particular suit was tested on subjects performing three different tasks: climbing through a horizontal confined space, vertical confined space (pit), and loading and unloading material using a wheel barrow. Multiple test subjects performed each task for 20 minutes each. Performance of the innovative suit was compared to two commonly used types of protective clothing. Vital statistics, including body temperature and heart rate, were continuously monitored and recorded by an authorized physician. A summary of the demonstration will be included in the October monthly report. Along with the MTR Chemical Protective Suit, the VitalSense{trademark} Telemetric Monitoring System from Mini Mitter Co., Inc. was evaluated. A summary of the demonstration will be included in the October monthly report. A Kool-Vest from MicroClimate Systems, Inc. was evaluated during assessment at Beaver, WV from 8/16/99 to 8/17/99. The evaluation was performed in the same manner as the MTR Chemical Protective Suit described above. A summary of the demonstration will be included in the October monthly report. A brochure announcing the new Gateway to Environmental Technology (GET) website was produced by FIU-HCET and is being distributed to the D&D community by FETC-DDFA. The website provides links to the TIS and other decision support systems developed at FIU-HCET