z-logo
open-access-imgOpen Access
Hanford Tank Farms Vadose Zone, Addendum to the TX Tank Farm Report
Author(s) -
Robert Spatz
Publication year - 2000
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/765941
Subject(s) - environmental science , addendum , logging , vadose zone , hanford site , hydrology (agriculture) , usable , saturation (graph theory) , petroleum engineering , geology , engineering , soil science , waste management , forestry , geotechnical engineering , radioactive waste , geography , computer science , soil water , political science , law , mathematics , combinatorics , world wide web
This addendum to the TX Tank Farm Report (GJO-97-13-TAR, GJO-HAN-11) published in September 1997 incorporates the results of high-rate and repeat logging activities along with shape factor analysis of the logging data. A high-rate logging system was developed and deployed in the TX Tank Farm to measure cesium-137 concentration levels in high gamma flux zones where the spectral gamma logging system was unable to collect usable data because of high dead times and detector saturation. This report presents additional data and revised visualizations of subsurface contaminant distribution in the TX Tank Farm at the DOE Hanford Site in the state of Washington