Final Report: Development of X-ray tracer diagnostics for radiatively-driven ablator experiments, November 1, 1997 - October 31, 1998
Author(s) -
J. J. MacFarlane,
David H. Cohen,
G.A. Ping Wang,
R.R. Moses,
P A Peterson,
Jaanimagi,
O. L. Landen,
Richard E. Olson,
T. J. Murphy,
G. R. Magelssen,
N. D. Delamater
Publication year - 1999
Language(s) - English
Resource type - Reports
DOI - 10.2172/765573
Subject(s) - hohlraum , tracer , national ignition facility , laser , optics , materials science , inertial confinement fusion , spectroscopy , plasma diagnostics , physics , plasma , nuclear physics , astronomy
This is a combined experimental and theoretical analysis of tracer layers as spectral diagnostics for radiation burn-through of ablator materials. German-doped plastic is attached as a witness plate to a laser driven hohlraum. Backlit absorption spectroscopy is used as a diagnostic. Target shots were performed on the OMEGSA laser at UR/LLE