PUREX Plant waste analysis plan. Revision 2
Author(s) -
C.N. Villalobos
Publication year - 1995
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/64196
Subject(s) - purex , plan (archaeology) , waste management , environmental science , radioactive waste , engineering , chemistry , geography , archaeology , chromatography , extraction (chemistry) , solvent extraction
A Washington Administrative Code 173-303-300 requires that a facility develop and follow a written waste analysis plan which describes the procedures that will be followed to ensure that its dangerous wastes are managed properly. This document covers the activities at the PUREX Plant to characterize the designate waste that is generated within the plant, stored in Tanks F18, U3/U4, and managed through elementary neutralization in Tank 31
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom