RHIC injection kicker impedance
Author(s) -
V. Mane,
S. Peggs,
D. Trbojevic,
W. Zhang
Publication year - 1995
Language(s) - English
Resource type - Reports
DOI - 10.2172/61184
Subject(s) - electrical impedance , ohm , calibration , strips , materials science , acoustics , ceramic , copper , electrical engineering , physics , composite material , engineering , metallurgy , quantum mechanics
The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated