Thermal resistance across a copper/Kapton/copper interface at cryogenic temperatures
Author(s) -
Liuxian Zhao,
Patrick E. Phelan,
R. C. Niemann,
Birgit Weber
Publication year - 1997
Language(s) - English
Resource type - Reports
DOI - 10.2172/554889
Subject(s) - kapton , copper , materials science , thermal resistance , composite material , thermal conduction , thermal conductivity , heat sink , thermal , layer (electronics) , metallurgy , electrical engineering , polyimide , thermodynamics , physics , engineering
The high-{Tc} superconductor current lead heat intercept connection, which is utilized as a thermal intercept to remove the Joule heat from the upper stage lead to a heat sink operating at 50--77 K, consists of a structure where a 152-{micro}m film is sandwiched between two concentric copper cylinders. The material chosen for the insulating film is Kapton MT, a composite film which has a relatively low thermal resistance, but yet a high voltage standoff capability. Here, the measured thermal conductance of a copper/Kapton MT/copper junction in a flat-plate geometry is compared to the results obtained from the actual heat intercept connection. Increasing the contact pressure reduces the thermal resistance to a minimum value determined by the film conduction resistance. A comparison between the resistance of the copper/Kapton MT/copper junction and a copper/G-10/copper junction demonstrates that the Kapton MT layer yields a lower thermal resistance while still providing adequate electrical isolation