z-logo
open-access-imgOpen Access
Thermal stability of LX-09 chemical reactivity testing. Final report
Author(s) -
Andrzej Teter
Publication year - 1971
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/525048
Subject(s) - sample (material) , materials science , mathematics , composite material , chemistry , chromatography
Several CRT tests were performed with LX-09 using sample containers obtained from LLL. These containers were used to help eliminate differences that were inherent in the design of the various sample containers used by the different laboratories. Initial experiments showed poor agreement in test data between LLL and Pantex containers until Pantex containers were fitted with different valves. Later experiments show no significant differences in test data between the two types of containers after the modification. Fillers of stainless steel (used in LLL containers) and of glass (used in Pantex containers) were interchanged with-out significant differences in results. Results of tests with PBX 9404 and with LX-04-1 are included

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom