Final report for tank 241-BX-112, auger samples 95-Aug-047 and 95-Aug-048
Author(s) -
J.M. Conner
Publication year - 1996
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/492098
Subject(s) - auger , explosive material , sampling (signal processing) , detection limit , limit (mathematics) , space (punctuation) , flammability limit , raw data , analytical chemistry (journal) , nuclear engineering , materials science , chemistry , physics , engineering , computer science , chromatography , atomic physics , mathematics , optics , thermodynamics , detector , operating system , ignition system , organic chemistry , programming language , mathematical analysis
This document serves as the final report for Tank 241-BX-112. The auger samples were taken on Nov. 16 and 17, 1995. The report is broken into 2 parts; the nd part consists of the original 45-day safety screening report (including the DSC and TGA raw data). Prior to auger sampling, the vapor space of tank BX-112 was screened for flammability issues; the vapor space was found to be far below the lower explosive limit. The auger samples were taken to fully satisfy the DQO