z-logo
open-access-imgOpen Access
High SO{sub 2} removal efficiency testing: Evaluation of high efficiency test results at Hoosier Energy`s Merom Station
Publication year - 1996
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/481948
Subject(s) - alkalinity , sulfite , reagent , chemistry , sulfur , formate , process engineering , waste management , environmental science , engineering , inorganic chemistry , organic chemistry , catalysis
Tests were conducted at Hoosier Energy`s Merom Station 535-MW Units 1 and 2 wet limestone flue gas desulfurization (FGD) systems to evaluate options for achieving high SO{sub 2} removal efficiency. The options tested included use of dibasic acid (DBA) and sodium formate additives as well as operation at higher reagent ratios (higher pH set points). In addition to the tested options, the effectiveness of other potential options was simulated using the Electric Power Research Institute`s FGD Process Integration and Simulation Model (FGDPRISM) after it was calibrated to the system. An economic analysis was done to determine the cost effectiveness of each option. A summary of results is given on the following: SO{sub 2} removal performance; additive consumption; and SO{sub 2} removal upgrade economics

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom