Maintenance building structural design description: 4 x 350 MW(t) Modular HTGR [High-Temperature Gas-Cooled Reactor] Plant
Publication year - 1986
Language(s) - English
Resource type - Reports
DOI - 10.2172/464077
Subject(s) - roof , reinforced concrete , structural engineering , geotechnical engineering , engineering , geology
The Maintenance Building is a grade-founded, two-story, steel-framed structure, located adjacent to the Turbine Building in the Energy Conversion Area. It has a reinforced concrete foundation and slab on grade, and insulated sheet metal exterior walls and roof decking