STANDARD OPERATING PROCEDURE FOR TSR-II
Author(s) -
Jonathan S. Lewin
Publication year - 1960
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/4156581
Subject(s) - shutdown , tower , electromagnetic shielding , nuclear engineering , reliability engineering , environmental science , computer science , engineering , electrical engineering , structural engineering
The daily check list, the startup procedure both for in-pool and in-air operation, and the normal shutdown procedure for the Tower Shielding Reactor-II are outlined. The sequence of events which leads to each annunciator warning and the automatic corrective action which is then initiated by the control circuits are described. (auth