z-logo
open-access-imgOpen Access
Stability of purgeable VOCs in water samples during pre-analytical holding: Part 1, Analysis by a commercial laboratory
Author(s) -
O.R. West,
C.K. Bayne,
R.L. Siegrist,
Wendy Holden,
S.S. Scarborough,
D. Bottrell
Publication year - 1996
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/410334
Subject(s) - acrolein , environmental chemistry , chemistry , chromatography , vial , environmental science , organic chemistry , catalysis
This study was undertaken to examine the hypothesis that prevalent and priority purgeable VOCs in properly preserved water samples are stable for at least 28 days. (VOCs are considered stable if concentrations do not change by more than 10%.) Surface water was spiked with 44 purgeable VOCs. Results showed that the measurement of 35 out of 44 purgeable VOCs in properly preserved water samples (4 C, 250 mg NaHSO{sub 4}, no headspace in 40 mL VOC vials with 0.010-in. Teflon-lined silicone septum caps) will not be affected by sample storage for 28 days. Larger changes (>10%) and low practical reporting times were observed for a few analytes, e.g. acrolein, CS{sub 2}, vinyl acetate, etc.; these also involve other analytical problems. Advantages of a 28-day (compared to 14-day) holding time are pointed out