EXAMINATION OF COMPONENTS FOR CRUD AND CORROSION 1-B HEAT EXCHANGER HANDHOLE AREA. CORE I, SEED 1. Test Results T-612080
Publication year - 1960
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/4094936
Subject(s) - heat exchanger , corrosion , core (optical fiber) , metallurgy , materials science , chemistry , nuclear engineering , physics , engineering , composite material , thermodynamics
The extent and location of corrosion, crud deposits, and defects in the ends of the 1-B heat exchanger after removing the handhole covers were determined. There was no visual evidence of pitting or corrosion inside the ends of the heat exchanger. A radiochemical analysis of a smear sample taken from the inside of number one handhole showed the presence of the following isotopes- Fe/sup 59/, Co/ sup 58/, s1>s, and Zr/sup 95/. A radiation survey performed in four handholes indicated a maximum level of 1 r/hr. (W.L.H.