FLOW DISTRIBUTION ACROSS THE CORE. CORE I, SEED 2, Section 2. Test Results T-550097
Publication year - 1961
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/4048880
Subject(s) - section (typography) , core (optical fiber) , distribution (mathematics) , flow (mathematics) , mathematics , geology , computer science , geometry , telecommunications , mathematical analysis , operating system
An investigntion was conducted to determine the reactor coolant mixing charactsristics of the inlet plenum chamber. It was found that mixing in the inlet plenum was slight, and flow from a given loop is corfined mainly to its quadrant of the core. There appears to be no significant change in the flow rate through the fuel assemblies monitored with the reactor coolant introduced at various temperatures and the reactor coolant pump on either fast or slow speed. (J.R.D.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom