PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results
Publication year - 1961
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/4027929
Subject(s) - leak , leakage (economics) , buoyancy , test method , leak detection , engineering , environmental science , nuclear engineering , mechanics , mathematics , statistics , environmental engineering , physics , economics , macroeconomics
An investigation was made to determine the magnitude and location of the reactor coolant system leakage of the Shippingport Power Beactor. The "total" plant leakage was indicated by the pressurizer level change since no make-up was added during the test. The "accounted for" leakage was indicated by the flash tank level change and the blowoff tank level change. The relief valves from the pressurizer and reactor were checked for leakage individrually and a combined leakage of 2.84 gal/hr was obtainsd for the 6 valves tested. The system was found to have a total leak rate of 5.65 gal/hr of which 1.17 gal/hr was "accounted for." (M.C.G.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom