PERIODIC CALIBRATION OF TEMPERATURE SENSING ELEMENTS. CORE I, SEED 2. Test Results (T-641303-B)
Author(s) -
Not Given Author
Publication year - 1961
Language(s) - English
Resource type - Reports
DOI - 10.2172/4010189
Subject(s) - calibration , core (optical fiber) , core temperature , instrumentation (computer programming) , range (aeronautics) , atmospheric temperature range , open source , data source , environmental science , remote sensing , analytical chemistry (journal) , chemistry , physics , materials science , geology , meteorology , computer science , database , environmental chemistry , optics , operating system , composite material , medicine , software , quantum mechanics , anesthesia
Tests were conducted to determine the direction and magnitude of any short- or long-term drift in core thermocouples, primary loop and pressurizer resistance thermometers, and resistance thermometers located in the secondary side of the boilers for Seed 2 at 2303 EFPH. It was found that drift in the core thermocouples is definite but random. Other findings are discussed and calibration data are presented graphically. (J.R.D.