Results of fracture mechanics analyses of the ederer cranes in the device assembly
Author(s) -
E.N.C. Dalder
Publication year - 1996
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/385504
Subject(s) - flange , fracture mechanics , fracture (geology) , structural engineering , engineering , beam (structure) , forensic engineering , mechanical engineering , geotechnical engineering
Fracture mechanics analyses were conducted on three critical locations on the lower flange of the load-beam of the Ederer 5 ton and 4 ton cranes in the D.A.F. Facility. Based on these results, it appears that: 1. Propagation of a 5 mm long flaw, previously undetected by non-destructive examination (NDE), to a length sufficient to cause structural failure of either flange, should not occur in at least 100 times the postulated operating scenarios for each crane; 2. Should each crane undergo annual inspection, any surface flaw with a length greater that 20 mm should be removed and repaired by qualified and approved repair procedures
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom