Stainless steel quadralatch finger test report
Author(s) -
P.R. Deichelbohrer
Publication year - 1996
Publication title -
osti oai (u.s. department of energy office of scientific and technical information)
Language(s) - English
Resource type - Reports
DOI - 10.2172/362375
Subject(s) - design for manufacturability , flammable liquid , mechanical design , engineering , mechanical engineering , electrical engineering , environmental science , waste management
The design of the quadralatch on the universal samplers was changed in response to flammable gas operating constraints. Additional redesign of the fingers was included to facilitate manufacturability. The new design was tested to assure satisfactory performance. It was shown that the fingers can hold a sampler in place with an upward force of at least 2200 N (500 pounds) and that the mechanical remote latch unit can release the quadralatch under this condition of maximum upward force
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom